Showing posts with label Solar PV. Show all posts
Showing posts with label Solar PV. Show all posts

Friday, May 13, 2011

Solar power update

Various snippets of news ...

EDF have told us that the first FIT payment and payment for electricity supplied to the grid is about to be transferred into our bank account. A mere £19 or so, this being for the 45 units we generated from mid-December to the end of February - but you have to start somewhere.

The reading was requested in March, and I sent it on 1st March - incidentally, just before the system really started to get going. As I mentioned in an earlier post, EDF only undertook to make the payment within 90 days of the end of the month that the reading was taken - which would have been the end of June, basically. So it was reassuring to be told it would be arriving six weeks earlier than that. I don't know if had I taken the reading later in the month, whether I'd have got the payment at the same time.

The next payment will be for electricity generated from March 1 to the end of May, and will be somewhat more substantial - we're running at an average of around 7 units per day at the moment, and I think we'll be claiming for around 500 kWh for those three months.

The amount of electricity we are drawing from the mains is lower - and noticeably lower on bright days than on dull days. Several years ago, we seemed to be using an average of around 20-22 units per day, all year round. I think our usage is somewhat less than that now - partly due to the replacement of appliances with more efficient ones, and use of low energy lightbulbs, over the last few years; partly due to the feedback from the energy monitor that we have - in the last few months of the winter, it sometimes spiked at over 20 units per day, but the average was around 17. Less power is used for lighting and so on in the summer, so that would bring it down a bit further. But the seven-day moving average of electricity units drawn from the main has actually been below 10 since early April. For a few days in the clear, bright weather at the start of May, we were generating over 11 kWh per day, and the moving average of the amount we were generating was actually above the moving average of the amount we were using.

Monday, May 09, 2011

The FIT scam

It sounds fairly scammy that the government should pay people for generating solar power, far more than the electricity costs to generate or that any company can sell the electricity for. However, this is a government scheme to encourage uptake of microgeneration of electricity. There was a grants regime before, and this has replaced it. And the payback time is still likely to be over a decade - worthwhile, but you need to have a long view.

What is more of a scam is the electricity company role in this. The standard regime is that electricity that we generate and don't use we get paid 3p per unit for. The electricity doesn't bother metering it - they have decided to pay us for half the units we generate. The payment scheme for this is that they say they will pay us within 90 days of the end of the month on which the meter reading was taken. And herein lies the scam.

The next meter reading I do is due in June. Let's say I do it on June 1st. It will relate to the electricity I generated in March, April and May, which will amount to around 500 units, let's say - worth £200 of Feed-In Tariff payments. A significant proportion of this electricity will have fed into the grid - let's say half. That is 250 units that the electricity company doesn't have to incur costs to generate in March-May. But they don't have to pay for them until 90 days after the end of June - that is, the end of September. And when they do pay for them, they only pay 3p per unit. In the meantime, they will have billed and collected their standard rate for them - 12-13p per unit at the moment.

I hadn't put the numbers together when I had this installed just how good a deal it is for the electricity companies. Ours is already exploiting our direct debit scheme to ensure that they are almost always sitting on (and earning interest on) several hundred pounds of credit balance on our account. The companies pushed people to take up direct debit, on the basis of convenience, and a small reduction in charges - but if our experience is typical, they are probably sitting on, and earning interest on, several hundred million pounds of prepayments. Add to this the FIT scheme - it makes it clear that the main short-term beneficiaries of the scheme are not the people who have the systems installed, but the electricity companies.

Thursday, April 14, 2011

The behaviour of the PV system

Some interesting and curious phenomena are coming to light (if you are a PV geek).

Yesterday was the first time in a week that we didn't get close to 8 kWh. It was pretty cloudy all day, with occasional light drizzle. However, we still managed to generate 4.7 kWh - which is as near as anything to what we hope to see as an average for the year.

Phenomenon 1: When it's cloudy, the PV system comes on earlier.

On sunny days, it can be quite late by the time the inverter switches on - even now, around 9.00 (which, with daylight saving, is close to 0800 in "solar time", where you base noon on the time the sun is closest to overhead). It seems to be the case that if it's cloudy (but reasonably light) it comes on earlier - today it was on a good hour earlier than that. I think this is because one of the effects of the clouds is to diffuse the sunlight across the sky. As long as the cloud cover is not too thick, the brightness of a cloudy sky overall tends to be greater than the brightness of a blue sky.

Obviously, without direct sunlight, the panels won't generate as much power as in sunshine. However, this brings me to ...

Phenomenon 2: The highest output peaks come not on the sunniest days, but on sunny intervals on cloudy days.

In theory, the output of our inverter should not exceed 2000 W. The running output we have been led to expect is around 1800 W. Look at the peak output from the last few days:
DatePeak output/WTotal output/kWh
06 Apr17418957
07 Apr16098750
08 Apr15848454
...
12 Apr19927912
13 Apr19304701
6-8 April saw us in settled anticyclonic weather. I suspect that the reason for the gradual decline in peak output (and total output) was that this sort of high pressure results in a haze layer gradually building from ground level up. Barely perceptible, particularly to begin with, it does however lead to the rise in hayfever conditions at this time of year! However, it may be thick enough to gradually result in more of the sunlight not arriving at the solar panels.

12 and 13 were both cloudy; 12 intermittently cloudy, and 13 as I said earlier on, fairly steady grey. However, on both days, peak output was higher than in the anticyclonic weather. There are a couple of possibilities for this. The first is that it was no more than a momentary spike, and it wouldn't have maintained it for any length of time. The second is that the haze layer is significantly less defined outside the anticyclonic conditions, and when the sun was able to break through the cloud, the solar system was able to generate a higher power.

This requires a little more research, which will be easier when the promised PC interface card arrives - we can see just how much time is spent at high power on the less sunny days. It is certainly satisfying to see the LED on the solar output meter blinking away every two seconds as another Wh is generated in bright weather.

Monday, April 11, 2011

Solar PV in spring

We've had six lovely sunny days, generally warm, with largely clear skies. Trees have been covered with blossom and the bright green leaves of the new year.

The output of the solar system has increased accordingly. On each day, we've generated around 8-9 units - a good result for the whole year would be an average of 5 units per day - and peak output has been 1600-1700 watts. The total output for the six days has been more than we claimed for the first three months that the system was installed!

I suspect peak output won't increase greatly - we get odd spikes up towards the 2000 watt point, but it rarely seems to run steadily with this output - I hope that the system will generate closer to the peak for a larger proportion of the day as the summer goes on. At the moment, on a clear day, there is a fairly slow increase from around 9 am (0800 GMT) when the system typically comes onto around 11 am, with the output increasing from around 100 to 400 watts. Then it increases more quickly to its "high output" state, around 1500 watts, as the sun increasingly illuminates both banks of panels, and then starts to drop away fairly abruptly at around 3.30 pm (1430 GMT) as the sun gets closer to the treeline behind the house.

Monday, March 28, 2011

Solar update

Today, the five-day moving average of electricity generated per day clicked over 5 kWh (and, for that matter, over 6kWh). We've had odd days when the amount generated has been up to nearly 8 kWh, but this has been the first time when the average has been consistently above the 5 unit point.

The significance of this is that, to make the money that Rayotec claimed for the system, we need to generate around 5 units per day, averaged over the whole year.

We've been monitoring energy usage closely as well, and it's interesting watching the falling trend here. This is partly due to the increase in generated electricity that we have been able to use, but also because as the days get longer and milder, less electricity is used generally.

The next interesting milestone will be when we see a day on which we generate more electricity than we use.

Sunday, March 20, 2011

More about where we are with solar power

Up to now, the peak time of electrical generation for our system has been roughly between midday and 3pm, when the sun is shining directly onto the panels. Increasingly over the last few weeks, as the sun has got higher in the sky, the solar panels have been reaching their "peak" earlier in the day. The peak on a sunny day corresponds to an output of between 1500 and 1800 W, though we have measured outputs close to the maximum output possible of the inverter (2000W). The power tends to drop off after around 3pm, as the sun gets close to the treeline behind the house. Again, this should get better as the sun gets higher in the sky.

The most effective way of using the generated power would be for us to use as much of it as possible. We are paid (3p per unit!) for half the units we generate anyway, regardless of how much (or little) goes back into the grid, so we might as well use what we can.

Our house seems to have several "modes" of using power, and none of them really fit with the output of the solar system. During the day, the house tends to tick over at somewhere between 300W and 500W, assuming nothing much is happening. At night, once lights go on, it tends to sit between about 600W and 800W - though there's not much the solar system can do about that. As soon as appliances are on, this increases - but appliances rarely draw power continually, even if they need quite a lot. The kettle, for example, uses around 3kW - but only runs for a couple of minutes. The washing machine, ovens, the iron and so on can draw around 2000W, but not for the whole time they are on. The electric shower is by far the most demanding electrical thing in the house, but it's not used a large fraction of the time (fortunately!!).

So assuming the solar system is producing a healthy output, even having appliances on is not likely to consistently use all of its output. Unless a load of things are on at the same time, a significant amount of the power is likely to end up going into the grid.

However, on even a reasonably bright day, within three months of the summer solstice, the solar system seems to be able to cover the bulk of the "background" power use from say around 10am to 3pm - 1.5-2 units, and perhaps some of the use of appliances during the day. So we are trying to shift our behaviour - to put the dishwasher on after breakfast, to delay the washing machine and dryer to later in the day, or run it at weekends. The difficulty of managing our electricity usage to get the most out of the solar system during the daytime highlights how significant the feed-in tariff is in making the cost of the system bearable. Micro-generation of electrical power is an asset, however small, for the country as a whole. Whether it is worth 41p a unit is debatable, but without the FIT encouraging the take-up of such schemes, it would be hard for a person to justify its take up in economic terms.

The new option of a domestic fuel cell is potentially very interesting. This adjusts its supply of electricity to match demand - day or night - and when it can't supply enough, the grid supplies the shortfall. The grid will get a lot less from this form of micro-generation - but the proportion of a household's electricity that it is likely to cover would be substantially higher.

Wednesday, January 26, 2011

Solar PV - the difference a month makes

It's not that loads has changed - the days since we had the solar panels installed have been predominantly grey - well, this is an English winter, after all. However, the system is responding differently already. Even on the greyest day, the panels seem to be generating power from around 9.30 to around 3.30, and we rarely seem to have the "zero output" days that we had for the first few weeks.

There hasn't been a huge change in the sun. In the first month after the winter solstice, the noon position of the sun only gets three degrees higher in the sky, and the day gets less than an hour longer. However, it is evidently enough to take it closer to the light threshold at which the panels start to generate.

We have discovered that the panels weren't optimally connected to the inverter (the south and the west facing panels should have been connected as separate "strings" into the inverter, and they were in fact all linked in series), so Rayotec are coming back to rewire a section of the system. I'm hoping that they are going to find out how much it would cost to install the PC interface module at the same time. I don't know whether this will have a noticeable effect on the performance of the system. In theory, the output of the two different sections of panels can be optimised separately by the inverter: I don't know whether this is likely to give a 1% or a 10% improvement.

The peak output of the system so far has been just over 1000 W - it has reached that on four days, the first after the solstice being 9th January - and the highest total output we've seen has been about 2 KWh. The total output of the system since installation is a mere 13 units, though we lost a couple of days which ought to have been good as a result of our messing around with the system.

Saturday, December 25, 2010

Best PV day so far

Today was bright, though somewhat hazy for much of the day. However, it was still our best day so far from the point of view of collecting solar electricity. The peak output of our 2.3kWp system was 397 W, and the total power generated was 1106 Wh.

I mentally batted around some figures, to see if I could calculate from this whether the estimates made by the installing company were reasonable. We are at 50° north (near enough), and since we are at the winter solstice (near enough) the Sun was at 22° south. That means the highest it gets into the sky (at noon) would be to an elevation of about 18°. In the summer, with the sun at 22° north, it will reach an elevation of 62°. Assuming the relative amount of incident radiation varies with the sine of the angle of elevation (from zero at 0° to 1 at 90°), the sun will be (0.883/0.309), 2.85 times more intense on the basis of its angle of elevation in the summer. With the sun flatter in the sky, its radiation will also be attenuated to a greater extent by the depth of atmosphere through which the light has to travel. The modelled estimate of a 1600-1700 W or thereabouts peak in the summer - around 4 times the level we saw today - seems to be a sensible ballpark. We shall see.

Happy Christmas!

Monday, December 20, 2010

More PV information

The scaffolding to put the solar panels up hadn't been removed yet, and hadn't quite been properly blocked. So I climbed up to the roof this morning and had a go at sweeping the five inches of snow away that was sitting on the panels, and stopping them from working. In combination with a slight thaw (2 degrees during the day) and doubtless the dark colour of the photocollector helping to warm the surface up, a lot of the snow and ice on the panels was removed. As a consequence, in some weak winter sunshine, we reached a peak power output of 134 W, and managed to harvest about 112 Wh - still hardly impressive, but a step up from the zero that had been generated in the last few days.

Some more technical details about the installation. It uses 10 x 230Wp Schott panels - it is thus a 2.3 kWp (kilowatt peak) system - and a StecaGrid 2010+ inverter. The efficiency of the inverter is pretty high - even at a 5% load, it is nearly 80% efficient; its published efficiency is given as 93.3%, which is the efficiency it achieves at 30% of its nominal power, 2000W.

Rayotec give a written quotation of the expected performance of the system. They estimate (based on a mathematical model) that the irradiation of the PV array over the course of a year will be about 16,400 kWh, and the amount of power generated will be around 10% of this, 1,683 kWh. This equates to about 729 kWh/kWp.

Tuesday, December 14, 2010

Quick PV update

I had a look at the data gathered so far - it was only on for a couple of hours fairly late this afternoon. The peak power generated was 181 W, and it has generated 90 Wh so far - enough to run an old-fashioned lightbulb for an hour and a half, in other words.

I'm wondering now about whether it's possible to get the PC/Ethernet interface card added post-installation.

Solar panel installation - photos

Under the stairs - big red isolation switch, and meter. Since we now have two sources of power, both the mains electricity and the inverter need to be switched off prior to any work being carried out. The solar supply feeds a line into the consumer unit, as far as I can tell. Incidentally, in the event of a power cut, or loss of AC for other reason (such as the main RCD tripping), the inverter is switched off, and waits for three minutes after power is restored prior to being re-energised.
The inverter, in the roof space. I may regret having it installed up there. The inverter generates and stores lots of data. Even in the fading light, there was something quite fascinating about watching the changing power output of the system. But I'd rather not sit in the loft and do that ....

Monday, December 13, 2010

Solar panel installation

... this started happening today.

The scaffolding team arrived last Tuesday. They had rung on Monday to say that they couldn't make it in on that day, but would come on the Tuesday. This was something of a surprise, since I was pretty sure they weren't due to be there till Wednesday. However, since they were happy to install it without our actual presence, it didn't matter that much.

They rang again on Tuesday morning, to confirm they would be there at 11ish. We were both out at work by then. By the time we got home, the scaffolding was all in place.

Despite potential disruption due to weather, the roof installation team arrived at 9am this morning. The electrician rang at 9.30, to say he'd be there a little later - which he duly was. The installation has proceeded smoothly so far, the only slight complication being that the panels on one section of the roof don't fit in a tidy array, so three will be lined up "portrait" and two running along the bottom of the roof section "landscape". The panels aren't up yet, but the metal framework that will support them is.

As far as cabling is concerned, the inverter will be in the loft, mounted on a board next to the chimney breast. A cable runs from there close to the boiler and then down to the consumer unit area, using cable ties to fix it to the pipe that takes gas up to the boiler. A meter has been mounted, along with a meaty isolation switch - there will be photos soon!

The installation team have been pleased with how smoothly it has gone, and hope to have finished early - they are implying lunchtime, rather than school pickup time.